EasyManua.ls Logo

Tecnam P2010 - Defective Engine Controls

Tecnam P2010
587 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 3 - 18
2
nd
Edition, Rev.0
Section 3 Emergency procedures
POWERPLANT EMERGENCIES
6.10. DEFECTIVE ENGINE CONTROLS
Defective Mixture Control Cable
1. Maintain altitude to the nearest airfield
2. During descent, check engine behaviour to a higher power setting. A lean
mixture can lead to engine roughness and loss of power.
Landing approach must be planned accordingly.
WARNING
Go-around may then be impossible.
Defective Throttle Control Cable
If power is sufficient to continue flight:
1. Approach nearest airfield
2. Perform landing with shut-down engine applying Forced landing proce-
dure. (See Para 11)
If power is not sufficient to continue flight:
1. Carry out Forced landing procedure. (See Para 11)

Table of Contents