6.8. LOW FUEL PRESSURE
If fuel pressure decreases below the lower limit (14 psi)
1. Electric fuel pump………... ON
2. Fuel selector valve………... Select opposite fuel tank if NOT empty
3. Fuel quantity ……………... CHECK
If fuel pressure doesn‟t build up:
1. Land as soon as practical. Prepare for potential engine failure and pre-
pare to apply Forced landing procedure. (See Para 11)
6.9. HIGH FUEL PRESSURE
If fuel pressure increases above the upper limit (35 psi)
1. Land as soon as possible. Prepare for potential engine shut down and
apply Forced landing procedure. (See Para 11)
Possible injector failure or obstruction.