Section 3 Emergency procedures
AVIONIC SUITE FAILURES
3.7. DISPLAY FAILURE
In the event of a display failure, the G1000 System automatically switches to re-
versionary (backup) mode. In reversionary mode, all important flight information
is presented on the remaining display in the same format as in normal operating
mode. The change to backup path is completely automated for all LRUs and no
pilot action is required.
if the system fails to detect a display problem
1. REVERSIONARY MODE button
PUSH
REVERSIONARY MODE button is red and located on the bot-
tom of the audio panel .
CAUTION
If a display fails, the related Integrated Avionics Unit (IAU) is
cut off and can no longer communicate with the remaining dis-
play: subsequently the NAV and COM functions provided to the
failed display by the associated Integrated Avionics Unit are
flagged as invalid on the remaining display.
NOTE