EasyManua.ls Logo

Tecnam P2010 - Page 334

Tecnam P2010
587 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AFMS N°D03 FOR ALTERNATIVE AVIONICS CONFIGURATION
Page 3G-17
Section 3 Emergency procedures
POWERPLANT EMERGENCIES
Ed. 1, Rev.0
6.8 LOW FUEL PRESSURE
If fuel pressure decreases below the lower limit (14 psi)
1. Electric fuel pump………... ON
2. Fuel selector valve………..Select opposite fuel tank if NOT empty
3. Fuel quantity ……………..CHECK
If fuel pressure doesn‟t build up:
1. Land as soon as practical. Prepare for potential engine failure and
prepare to apply Forced landing procedure. (See Para 11)
6.9 HIGH FUEL PRESSURE
If fuel pressure increases above the upper limit (35 psi)
1. Land as soon as possible. Prepare for potential engine shut down and
apply Forced landing procedure. (See Para 11)
Possible injector failure or obstruction.

Table of Contents

Other manuals for Tecnam P2010

Related product manuals