Allowable frequency
fluctuation
±5%
* 1 Take standard 4-pole induction motor as the base.
* 2 HD (heavy load type): 150% / 1 min, 200% / 2sec, carrier range: 2KHZ ~ 16KHZ , the factory
setting is 8KHZ (220V ~ 20HP / 440V ~ 30HP).
* 3 HD (heavy load type): 150% / 1 min, 200% / 2sec, carrier range: 2KHZ ~ 12KHZ, the factory
setting is 5KHZ (440V 40 ~ 50HP).
* 4 HD (heavy load type): 150% / 1 min, 200% / 2sec, carrier range: 2KHZ ~ 12KHZ, the factory
setting is 6KHZ (220V 25HP).
* 5 HD (heavy load type): 150% / 1 min, 200% / 2sec, carrier range: 2KHZ ~ 12KHZ, the factory
setting is 5KHZ (220V 30 ~ 40HP).
* 6 HD (heavy load type): 150% / 1 min, 200% / 2sec, carrier range: 2KHZ ~ 10KHZ , the factory
setting is 5KHZ (220V 50 ~ 100HP/440V 60 ~ 175HP).
* 7 HD (heavy load type): 150% / 1 min, 200% / 2sec carrier range: 2KHZ ~ 8KHZ, the factory setting
is 3KHZ (440V 215HP).
* 8 ND (standard load type): 120% / 1 min, carrier range: 2KHZ ~ 16KHZ, the factory setting is 2KHZ.
* 9 A510 model is designed to use in heavy load conditions, the factory setting takes HD (heavy load
type) as the base.
* 10 if it is greater than factory carrier frequency, you need to adjust the load current based on the de-
rating curve.
* 11. 220V 125HP / 440V 250HP models or above are being developed.