4-212
4.4.3 Application command
1. Counter
c
Counting mode (1-4)
d
UP/Down counting modes can be set by (I1 ~ f8).
OFF:Up counting (0,1,2,3…)
ON: Down counting(…3,2,1,0)
e
Use (I1~f8) to reset counting value
ON : Count value resets and h is OFF
OFF : Count value keeps on counting
f
Present counting value of the counter
g
Counter setting action values (AS1~AS4,MD1~MD4,T1~T8,C1~C8,V1~V7,constant)
h
Counter number (from C1 to C8, there are 8 groups in total)
The description of counting mode
mode 1:
Count value is locked to the set value. The value will not be retained when the power is
cut off.
mode 2:
Count value is not locked. The value will not be retained when the power is cut off.
mode 3:
Count value is locked. The value will be retained when the power is cut off.
mode 4:
Count value is not locked. The value will be retained when the power is cut off.
(1) Counter mode 1
Example :
In
p
ut count
p
ulse