4-116
05- 33 Acceleration time setting of multi speed 8
05- 34 Deceleration time setting of multi speed 8
05- 35 Acceleration time setting of multi speed 9
05- 36 Deceleration time setting of multi speed 9
05- 37 Acceleration time setting of multi speed 10
05- 38 Deceleration time setting of multi speed 10
05- 39 Acceleration time setting of multi speed 11
5- 40 Deceleration time setting of multi speed 11
05- 41 Acceleration time setting of multi speed 12
05- 42 Deceleration time setting of multi speed 12
05- 43 Acceleration time setting of multi speed 13
05- 44 Deceleration time setting of multi speed 13
05- 45 Acceleration time setting of multi speed 14
05- 46 Deceleration time setting of multi speed 14
05- 47 Acceleration time setting of multi speed 15
05- 48 Deceleration time setting of multi speed 15
Range
0.0~6000.0 Sec
¾ When 05- 00 =0, the acceleration and deceleration time of multi-speec0~ 15
16 are determined by 00-14~00-17/00-21~00-24.
¾ When 05- 00 =1, the acceleration and deceleration time of multi-speec0~ 15
16 are calculated by 05- 17~05- 48 and not determined by
00-14~00-17/00-21~00-24.
Function description:
¾ When operating The formula of acceleration / deceleration time in operation: the
denominator takes the maximum output frequency as the base.
¾
When 01- 00=F, maximum output frequency =01-02 Setting 01- 00F,
maximum output frequency =50.00(or 60.00/90.00/120.0/180.0)
¾ Example01- 00F,01- 02=50hz ( maximum output frequency ), 05- 02=10hz (multi-step
speed 0),
05-17=5s(Acceleration time),05-18=20s(Deceleration time)then
A
cceleration time of reaching set
frequency
Maximum out
p
ut fre
q
uenc
y
A
cceleration time of
g
rou
p
0
x set fre
q
uenc
y
Deceleration time of group 0 x set frequency
Maximum output frequency
Deceleration time of reaching
set frequency
Actual acceleration time of speed 0
Actual deceleration time of speed 0
(parameter 05-17)x10Hz)
parameter 01-02
(parameter 05-18)x10Hz)
parameter 01-02