4-116
05- 33 Acceleration time setting of multi speed 8
05- 34 Deceleration time setting of multi speed 8
05- 35 Acceleration time setting of multi speed 9
05- 36 Deceleration time setting of multi speed 9
05- 37 Acceleration time setting of multi speed 10
05- 38 Deceleration time setting of multi speed 10
05- 39 Acceleration time setting of multi speed 11
5- 40 Deceleration time setting of multi speed 11
05- 41 Acceleration time setting of multi speed 12
05- 42 Deceleration time setting of multi speed 12
05- 43 Acceleration time setting of multi speed 13
05- 44 Deceleration time setting of multi speed 13
05- 45 Acceleration time setting of multi speed 14
05- 46 Deceleration time setting of multi speed 14
05- 47 Acceleration time setting of multi speed 15
05- 48 Deceleration time setting of multi speed 15
Range
【
0.0~6000.0】 Sec
¾ When 05- 00 =【0】, the acceleration and deceleration time of multi-speec(0~ 15)
16 are determined by 00-14~00-17/00-21~00-24.
¾ When 05- 00 =【1】, the acceleration and deceleration time of multi-speec(0~ 15)
16 are calculated by 05- 17~05- 48 and not determined by
00-14~00-17/00-21~00-24.
Function description:
¾ When operating The formula of acceleration / deceleration time in operation: the
denominator takes the maximum output frequency as the base.
¾
When 01- 00=【F】, maximum output frequency =01-02 Setting ,01- 00≠【F】,
maximum output frequency =50.00(or 60.00/90.00/120.0/180.0)
¾ Example:01- 00≠【F】,01- 02=【50】hz ( maximum output frequency ), 05- 02=【10】hz (multi-step
speed 0),
05-17=【5】s(Acceleration time),05-18=【20】s(Deceleration time),then