4-23
Group 05 Multi-Speed Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
Attrib
ute
05-48
Deceleration time
setting of multi speed
15
0.1~6000.0
10.0 s O O O O O O
Group 06 Automatic Programm Operation Function Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
Attrib
ute
0: invalid
1: Execute a single cycle
operation mode. Restart
speed is based on the
previous stopped speed.
2: Execute continuous cycle
operation mode. Restart
speed is based on the
previous stopped speed.
3: Afte the completetion of a
single cycle, the on-going
operation speed is based on
the speed of the last stage.
Restart speed is based on
the previous stopped speed.
4: Execute a single cycle
operation mode. Restart
speed will be based on the
speed of stage 1.
5: Execute continuous cycle
operation mode. Restart
speed will be based on the
speed of stage 1.
06-00
utomatic operation
mode selection
6: Afte the completetion of a
single cycle, the on-going
operation speed is based on
the speed of the last stage.
Restart speed is based on
the previous stopped speed.
0 - O O O X O X
06-01
Frequency setting of
speed-stage 1
0.00~400.00
0.0~1200.0 (when 00-31 = 1)
5.00 Hz O O O O O O *1
06-02
Frequency setting of
speed-stage 2
0.00~400.00
0.0~1200.0 (when 00-31 = 1)
10.00 Hz O O O O O O *1
06-03
Frequency setting of
speed-stage 3
0.00~400.00
0.0~1200.0 (when 00-31 = 1)
20.00 Hz O O O O O O *1
06-04
Frequency setting of
speed-stage 4
0.00~400.00
0.0~1200.0 (when 00-31 = 1)
30.00 Hz O O O O O O *1
06-05
Frequency setting of
speed-stage 5
0.00~400.00
0.0~1200.0 (when 00-31 = 1)
40.00 Hz O O O O O O *1