3-10
415(50) 101/205(50)
100%
5K 10K 16K
Rated Current(In)
Carrier Frequency(Hz)
Note: 101 and 205 type does not need to decrease the current rating in 50 degrees
ambient temperature.
3.2.4 Capacitor reforming Guide after long storage
For correct performance of this product after long storage before use it is important that
Inverter Capacitors are reformed according to the guide below:
Storage
time
Procedure to re-apply voltage
1year
Apply rated voltage(Note1) of inverter in the normal way
Between
1-2 years
Apply rated voltage of inverter to the product for one hour before using
the inverter
2 years
Use a variable AC power supply to
1. Connecting 25% rated voltage of inverter for 30 minutes.
2. Connecting 50% rated voltage of inverter for 30 minutes.
3. Connecting 75% rated voltage of inverter for 30 minutes.
4. Connecting 100% rated voltage of inverter for 210 minutes.
Once the procedures completed, inverter just can be used normally.
Note1Rated voltage: please refer the rated voltage according to model label of inverter.