3Read data Quantity1.
(Example)Set SLAVE station No:01, S310+ drive as forward run at frequency reference 60.0HZ.
ASCII Mode
Instruction Message Response Message (Normal) Response(Fault)
STX 3AH STX 3AH STX 3AH
SLAVE
Address
30H
SLAVE
Address
30H SLAVE
Address
30H
31H 31H 31H
Function
Code
31H
Function
Code
31H
Function
Code
39H
30H 30H 30H
Start
Address
32H
Start
Address
32H
Error Code
35H
35H 35H 32H
30H 30H
LRC CHECK
31H
31H 31H 44H
Quantity
30H
Quantity
30H
END
0DH
30H 30H 0AH
30H 30H
32H 32H
DATA
Number*
30H
LRC CHECK
43H
34H 37H
First DATA
30H
END
0DH
30H 0AH
30H
31H
Next DATA
31H
37H
37H
30H
LRC CHECK
33H
42H
END
0DH
0AH
RTU Mode
Instruction Message Response Message (Normal) Response(Fault)
SLAVE Address 01H SLAVE Address 01H
SLAVE
Address
01H
Function
Code
10H
Function
Code
10H
Function
Code
90H
Start
Address
High 25H
Start
Address
High 25H Error Code 52H
Low 01H Low 01H
CRC-16
High
CDH
Quantity
High 00H
Quantity
High 00H Low
FDH
Low 02H Low 02H
DATA Number * 04H
CRC-16
High 1BH
First
DATA
High 00H Low 04H
Low 01H