V TYPE Function is only For SG2-20VR-D, SG2-20VT-D
1 Function Summarize
1.1 Remote IO FunctionMaster-Slaver communication
1.2 IO Link Function
1.3 Modbus Slaver Station Function
2 Function Detail
2.1 Remote IO FunctionMaster-Slaver communication
2.1.1 Function Describe
SG2 Slavers Inputcoil Iand Outputcoil Qcan be used as SG2 Masters expansive
Inputcoil Xand Outputcoil Y
2.1.2 System Setting
2.1.2.1 Connected A and B lines of two V-type SG2as Figure1
2.1.2.2 Setting MMasterfor the instance of first SG2’s menu SET-- REMOTE
I/O
2.1.2.3 Setting SSlaverfor the instance of second SG2’s menu SET-- REMOTE
I/O
Figure1Master-Slaver communication connection
2.1.3 Example
2.1.3.1 Programming in SG2 Ladder on SG2 Master as followsrunning the
program and observing the states of expended input coils X and output
coils Y
X2――――――― Y1
X3――――――― Y2
Enable the input coils I2~I3 of SG2 Slaver according to coil X2~X3 on the SG2
Master. When enable I2 on SG2 Slaver, output Q1 and enable I3, output Q2.
Chapter 13 20 points V TYPE Function
I/O address Master station Slave station
Input coil I1~IC
Output coil Q1~Q8
Expand input coil X1~XC I1~IC
Expand output coil Y1~YC Q1~Q8
SG2 A B
Master
SG2 A B
Slaver