Commands Listed in Alphabetical Order
Conditions
This command re
quires the DPO4AUDIO application module for the
MDO4000/B/C series, or the MDO3AUDIO for MDO3000 series.
Group
Bus
Syntax
BUS:B<x>:AUDio:FRAME:SIZe <NR1>
BUS:B<x>:AUDio:FRAME:SIZe?
Arguments
<NR1> specifies the number of channels in each frame.
Examples
BUS:B1:AUDIO:FRAME:SIZE 2 sets the frame size to 2.
BUS:B1:AUDIO:FRAME:SIZE? might return :BUS:B1:AUDIO:FRAME:SIZE 8
indicating that the number of channels in each frame is set to 8.
BUS:B<x
>:AUDio:FRAMESync:POLarity
Specifies the frame sync polarity for the AUDIO bus - falling or rising edge.
Conditions
This command requires the DPO4AUDIO application module for the
MDO4000/B/C series, or the MDO3AUDIO for MDO3000 series.
Group
Bus
Syntax
BUS:B<x>:AUDio:FRAMESync:POLarity {FALL|RISe}
BUS:B<x>:AUDio:FRAMESync:POLarity?
Arguments
FALL
specifies the falling edge as the frame sync polarity.
RISe specifies the rising edge as the frame sync polarity.
Examples
BUS:B1:AUDIO:FRAMESYNC:POLARITY FALL sets the falling edge for frame
sync polarity.
BUS:B1:AUDIO:FRAMESYNC:POLARITY? might return
:BUS:B1:AUDIO:FRAMESYNC:POLARITY RISe indicating that the
polarity is set to Rise.