Commands Listed in Alphabetical Order
Syntax
BUS:B<x>:DISp
lay:FORMat
{BINary|HEXadecimal|ASCII|MIXed|MIXED2 |BLOCKHEX}
BUS:B<x>:DIS
play:FORMat?
Related Commands
BUS:B<x>:TYPe
Arguments
BINary All values are displayed in binary.
HEXadecimal All values are displayed in hexadecimal.
ASCII All values are displayed in an ASCII format, for RS-232 only.
MIXed Values are displayed in a mixture of hexadecimal, binary, and decimal,
depending on the field.
MIXED2 Values are displayed in a mixture of hexadecimal, binary, decimal and
ASCII, depending on the field.
BLOCKHEX Displays the 16-bits of each payload as a block of 4 hexadecimal
digits.
BUS:B<x>:DISplay:TYPe
Specifies the display type for bus. You can set up the bus to display the protocol
information, the logic waveforms that comprise the bus, or both.
Group
Bus
Syntax
BUS:B<x>:DISplay:TYPe {BUS|BOTh}
BUS:B<x>:DISplay:TYPe?
Arguments
BUS displays the bus waveforms only.
BOTh displays both the bus and logic waveforms.
BUS:B<x>:ETHERnet:PRObe
This command specifies the Ethernet probe type: differential or single-ended. The
default is DIFFerential.
B<x> is the bus number 1-4. 1-3 for the MDO4000C and
1-2 for the MDO3000.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.