Commands Listed in Alphabetical Order
Examples
BUS:B1:LIN:PO
LARITY IN VERTED
sets the polarity to INVERTED.
BUS:B1:LIN:POLARITY? might return BUS:B1:LIN:POLARITY NORMAL
indicating the polarity is normal.
BUS:B<x>:LIN:SAMPLEpoint
Specifies the point to sample during each bit period, as a percent, for the LINbus.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application
module for all 4000 series models, and the MDO3AUTO application module
for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:LIN:SAMPLEpoint <NR1>
BUS:B<x>:LIN:SAMPLEpoint?
Arguments
<NR1> is a percentage that represents the point at which to sample during each
bit period.
Examples
BUS:B1:LIN:SAMPLEPOINT 10 sets the sample point to 10% of the bit period
BUS:B1:LIN:SAMPLEPOINT? might return BUS:B1:LIN:SAMPLEPOINT 50
indicating that the sample point is set to 50% of the bit period
BUS:B<x>:LIN:SOUrce
Specifies the source waveform for the LIN bus.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application
module for all 4000 series models, and the MDO3AUTO application module
for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:LIN:SOUrce
{CH1|CH2|CH3|CH4|D0|D1|D2|D3|D4|D5|D6| D7|D8|D9|D10|D11
|D1
2|D13|D14|D15}
BUS:B<x>:LIN:SOUrce?
2-184 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO4000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4000B Series and is the answer not in the manual?

Tektronix MDO4000B Series Specifications

General IconGeneral
BrandTektronix
ModelMDO4000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals