Commands Listed in Alphabetical Order
MATH selects th
e math waveform as the source for the histogram.
REF<1–4> selects a reference waveform as the source for the histogram. The x
variable can b
e expressed as an integer ranging from 1 through 4.
Examples
HISTOGRAM:SOURCE CH1 enables the Channel 1 waveform to be compared
against the histogram box.
HISTOGRAM:SOURCE? might return :HIST OGRAM:SOURCE CH1, indicating that
the waveform for Channel 1 is the source for the histogram.
HIStogram:STARt? (Query Only)
Returns the time (horizontal) or vertical units value (vertical) of the first bin wher
e
the histogram data starts. The HIStogram:MODe must be either
HORizontal
or VERTical for a value to be returned. If the mode is OFF, an error event is set
and nothing is returned.
If the HIStogram:MODe is
HORizontal, the value returned is the time of the left
bin. If the HIStogram:MODe is
VERTical the value returned is the vertical units
value of the top bin. The returned value is an <NR3>.
Group
Histogram
Syntax
HIStogram:STARt?
Related Commands
HIStogram:END?
HIStogram:MODe
Returns
<NR3> showing the returned value.
Examples
HISTOGRAM:START? might return :HISTOGRAM:ST ART 2.0000E-06
indicating that the first bin is at 2 μs.
HORizontal? (Query Only)
Returns all settings for the horizontal commands.
Group
Horizontal