Commands Listed in Alphabetical Order
Aseriesofexam
ples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COUNt:HITS?
Related Commands
MASK:COUNt
MASK:COUNt:SEG<x>:HITS?
Returns
<NR1>
Examples
MASK:COUNT:TOTAL? might return :MASK :COUNT:TOTAL 150, showing 150
hits have occurred.
MASK:COUNt:SEG<x>:HITS? (Query Only)
This query returns the number of hits for the specified mask segment. There
are up to 8 segments.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COUNt:SEG<x>:HITS?
Related Commands
MASK:COUNt:HITS?
MASK:COUNt