Commands Listed in Alphabetical Order
Examples
POWER:SWLOSS:
DISPLAY ENERGYLoss
displays only energy loss measurements
in the results.
POWER:SWLOSS
:DISPLAY ?
might return :POWER:SWLOSS:DISPLAY ALL
indicating that the results displays both energy and power loss measurements.
POWer:SWLoss:GATe:POLarity
This command specifies the switching loss gate polarity.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:GATe:POLarity {FALL|RISe}
POWer:SWLoss:GATe:POLarity?
Arguments
FALL sets falling edge as the switching loss gate polarity.
RISe sets rising edge as the switching loss gate polarity.
Examples
POWER:SWLOSS:GATE:POLARITY FALL sets the gate polarity to Fall.
POWER:SWLOSS:GATE:POLARITY ? might return
:POWER:SWLOSS:GATE:POLARITY RISE indicating that the gate polarity
is set to Rise.
POWer:SWLoss:GATe:TURNON
This command specifies the gate turn on level for switching loss power
measurements.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:GATe:TURNON <NR3>
POWer:SWLoss:GATe:TURNON?
2-522 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual