Commands Listed in Alphabetical Order
Conditions
MDO4000/B/C mo
dels only.
Group
RF
Syntax
RF:RF_PHASe:VERTical:POSition <NR3>
RF:RF_PHASe:VERTical:POSition?
Related Commands
RF:RF_PHASe:VERTical:SCAle
Arguments
<NR3> is a floating point number that specifies the vertical position.
Examples
RF:RF_PHASe:VERTical:POSition —1 sets the vertical position of the RF
Phase vs. Time trace to –1 divisi
on.
RF:RF_PHASe:VERTical:POSition? might return 0.0E+0, indicating a
vertical position of 0.
RF:RF_PHASe:VERTical:SCAle
This command specifies the vertical scale for RF Phase vs. Time trace. For a signal
with constant amplitude, increasing the scale causes the waveform to be displayed
smaller. Decreasing the scale causes the waveform to be displayed larger.
Conditions
MDO4000/B/C models only.
Group
RF
Syntax
RF:RF_PHASe:VERTical:SCAle <NR3>
RF:RF_PHASe:VERTical:SCAle?
Related Commands
RF:RF_PHASe:VERTical:POSition
Arguments
<NR3> is a floating point number that specifies the vertical scale.
Examples
RF:RF_PHASe:VERTical:SCAle 50 sets the vertical scale to 50
degrees/division.
RF:RF_PHASe:VERTical:SCAle? might return 50.0000, indicating that the
vertical scale has been set to 50 degrees/division.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-579