Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:VALue
When the search condition is set to DATa, and the qualifier is set to
LESSthan, MOREthan, EQual, UNEQ ual, LESSEQual or MOREEQual,
this command
specifies the value to search for. When the search condition
is set to
DATa, and the qualifier is set to INrange or OUTrange, this
command specifies the lower limit of the range. (Use the command
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:HIVALue
to specify the upper limit of the range.) The default is all X’s (don’t care).
SEARCH<x> is the search number, which is always 1, and B<x> is the bus number
1-4. 1-3 f
or the MDO4000C and 1-2 for the MDO3000.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ET HERnet:DATa:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ET HERnet:DATa:VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:QUALifier
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:OFFSet
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:SIZe
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:HIVALue
Arguments
QString is a quoted string where the allowable characters are 0, 1, and X. The
allowable number of characters depends on the setting for size. (Use the command
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:DATa:SIZe to
specify size.) The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:ETHERn et:DATa:VALue
“00001000”
sets the binary data to search on to 00001000, assuming the
qualifier is set to
LESSthan, MOREthan, EQual, UNEQu al, LESSEQual or
MOREEQual,andDATa:SIZe is set to 1 byte
SEARCH:SEARCH1:TRIGger:A:BUS:B1:ETHERn et:DATa:VALue
“00001000”
sets the lower limit of the range to 00001000, assuming the qualifi
er
is set to
INrange or OUTrange,andDATa:SIZe is set to 1 byte.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-635