Commands Listed in Alphabetical Order
Arguments
CRCHeader sets
the error type to CRC header.
CRCTrailer sets the error type to CRC trailer.
SYNCFrame sets the error type to sync frame.
STARTupnosync sets the error type to start up with no sync.
NULLFRStatic sets the error type to null frame static.
NULLFRDynamic sets the error type to null frame dynamic.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:ERRTYPE SYNCFRAME sets
the error type to sync frame
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:ERRTYPE? might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:ERRTYPE CRCHEADER
indicating the FlexRay error type is CRCHEADER
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue
This command specifies the high value to use when searching on the FlexRay bus
frame ID field. (Use SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
FRAMEID:VALue to set the low value.) The search condition needs to be set
to IDentifier (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:FRAMEID:HIVALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:FRAMEID:HIVALue?
Arguments
<QString> is a quoted string representing the binary data string used for FlexRay
frame ID high value.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:FRAMEID:HIVALUE
“00101100101”
sets the frame id high value to 00101100101.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:FRAMEID:HIVALUE?
might return
2-656 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual