Menus
3-4 SPG600 & SPG300 Sync Pulse Generators User Manual
ANALOG SYNC (STD)
Selects a black burst signal for the analog outputs. Use the left (W) or right (X)
arrow button to select the signal. You can select Black Burst, Black with CF (for
NTSC or NTSC No Setup), or Black without CF (for PAL).
Press the ENTER button to confirm the selection.
ANALOG SYNC (OPT)
Selects a black burst signal for the optional analog outputs. Use the left (W) or right
(
X) arrow button to select the signal. You can select Black Burst, Black with CF
(for NTSC or NTSC No Setup), or Black without CF (for PAL). This menu item
is only available for the SPG600 Option 02.
Press the ENTER button to confirm the selection.
TEST SIGNAL (ANALOG)
Selects a test signal for the analog outputs. Use the left (W) or right (X) arrow
button to select Standard or Option (the SPG600 Option 02 only). When you
select either of these items and then press the ENTER button, you will access the
Test signal (analog) submenu. Refer to Test Signal (Analog) Submenu on
page 3-6 for detailed information.
TEST SIGNAL (SDI)
Selects a serial digital test signal for SDI outputs. Use the left (W) or right (X)
arrow button to select Standard or Option (the SPG600 Option 03 only). When
you select either of these items and then press the ENTER button, you will access
the Test signal (SDI) submenu. Refer to Test Signal (SDI) Submenu on
page 3-9 for detailed information.
TIMING (ANALOG)
Adjusts the timing offset for the analog output signals to the internal reference
signal (frame reset signal). Use the left (
W) or right (X) arrow button to select
CH-1, CH-2, CH-3, CH-4, CH-5, CH-6, CH-7, or CH-8 (CH-5 to CH-8 are only
available for the SPG600 Option02). When you select any of these items and then
press the ENTER button, you will access the Timing (analog) submenu. Refer to
Timing (Analog) Submenu on page 3-11 for detailed information.
TIMING (SDI)
Adjusts the timing offset for the serial digital output signals to the internal
reference signal (frame reset signal). Use the left (
W) or right (X) arrow button to
select SDI-1, SDI- 2, SDI-3, or SDI-4 (SDI-3 and SDI-4 are only available for the
SPG600 Option 03). When you select any of these items and then press the ENTER
button, you will access the Timing (SDI) submenu. Refer to Timing (SDI) Submenu
on page 3-12 for detailed information.