SPG600 & SPG300 Sync Pulse Generators User Manual 3-5
OVERLAY
Selects an item (logo or ID text) that is overlaid on the test signal and sets its
displayed position. Use the left (
W) or right (X) arrow button to select Analog
(STD), SDI (STD), Analog (OPT) (the SPG600 Option 02 only) or SDI (OPT)
(the SPG600 Option 03 only). When you select either of these items and then press
the ENTER button, you will access the Overlay submenu. Refer to Overlay
Submenu on page 3-13 for detailed information.
PAR AME TE R
Sets the resolution of the serial digital video signals, the insertion of the EDH
(Error Detection and Handling), and which component(s) of the serial digital signal
is(are) available. Use the left (
W) or right (X) arrow button to select SDI (STD) or
SDI (OPT) (SPG600 Option 03 Only). When you select either of these items and
then press the ENTER button, you will access the SDI Parameters submenu. Refer
to SDI Parameters Submenu on page 3-16 for detailed information.