Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 161
LIMIT:TEMPLATE:SOURCE CH2
specifies that the template waveform for limit tests is the waveform currently
acquired using channel 2.
LIMIT:TEMPLATE:SOURCE?
might return CH2, specifying that the template waveform source for limit tests is
the waveform currently stored as the channel 2 waveform.
LIMit:COMPARE:CH<x>, LIMit:TEMPLate, LIMit:TEMPLate:DESTination
LIMit:TEMPLate:TOLerance:HORizontal
(Requires TDS3LIM)
Sets or returns the amount, in units of horizontal divisions, by which the source
waveform is varied horizontally when creating the destination template
waveform.
Limit Test
LIMit:TEMPLate:TOLerance:HORizontal <NR3>
LIMit:TEMPLate:TOLerance:HORizontal?
<NR3> is the amount, in horizontal divisions, by w hich the source waveform is
horizontally modified to generate the template that is stored in the destination
reference. The range is 0 to 5 divisions.
LIMIT:TEMPLATE:TOLERANCE:HORIZONTAL 1.0
specifies that the source waveform is modified horizontally by ±1.0 horizontal
division when generating the template waveform.
LIMIT:TEMPLATE:TOLERANCE:HORIZONTAL?
might return 1.0, specifying that the source waveform is modified horizontally
by ±1.0 horizontal division when generating the template waveform.