Command Descriptions
2- 164
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
*LRN? (Query Only)
Returns a string listing the oscilloscope settings. You can use this string to return
the oscilloscope to the state it was in when you made the *LRN? query.
Miscellaneous
HEADer, SET?, VERBose
*LRN?
NOTE. The *LRN ? query always returns a string including command headers,
regardless of the setting of the HEADer command. This is because the returned
string is intended to be sent back to the oscilloscope as a command string. The
VERBose command can still be used normally to specify whether the returned
headers should be abbreviated.
*LRN?
a partial response might look like this:
:HEADER 1;:VERBOSE 1;:ALIAS:STATE 1;:ACQUIRE:MODE
SAMPLE;NUMAVG 16;NUMENV 16;STATE 1;STOPAFTER
RUNSTOP;:DISPLAY:COLOR:PALETTE:REGULAR NORMAL;:DISPLAY:STYLE:DOT-
SONLY 0;:DISPLAY:PERSISTENCE 0.0E0;CLOCK 0;GRATICULE
FULL;INTENSITY:WAVEFORM 65;BACKLIGHT HIGH;:DISPLAY:XY:MODE
OFF;YCHANNEL CH2;YREF OFF;:SELECT:CH1 0;CH2 1;CH3 0;CH4 0;MATH
0;REF1 0;REF2 0;REF3 0;REF4 0;CONTROL CH2;:HARDCOPY:FORMAT
PCXCOLOR;PORT FILE;LAYOUT LANDSCAPE;:HORIZONTAL:RESOLUTION
LOW;TRIGGER:POSITION 1.02E1;:HORIZONTAL:MAIN:SCALE
2.0E-4;:HORIZONTAL:DELAY:STATE 0;