EasyManuals Logo

Tektronix TDS3000 Series Program Manual

Tektronix TDS3000 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #248 background imageLoading...
Page #248 background image
Command Descriptions
2- 210
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
<x> specifies which waveform to use, where <x> = 1 is the “from” waveform,
and <x> = 2 is the “to” waveform.
FALL specifies the falling edge.
RISe specifies the rising edge.
MEASUREMENT:IMMED:DELAY:EDGE1 RISE
specifies that the “from” waveform rising edge be used for the immediate delay
measurement.
MEASUREMENT:IMMED:DELAY:EDGE1?
returns either RISE or FALL.
MEASUrement:IMMed:SOUrce
Specifies the source to measure “from” when taking an immediate delay
measurement or phase measurement. This command is the same as the MEA-
SUrement:IMMed:SOURCE1 command.
MEASUrement:IMMed:SOURCE<x>
Specifies the source to measure “from” or “to” when taking an immediate delay
measurement or phase measurement.
Measurement
MEASUrement:IMMed:SOURCE<x> { CH<x> | MATH | MATH1 | REF<x> }
MEASUrement:IMMed:SOURCE?
SOURCE<x> specifies which waveform to use, where <x> = 1 is the “from”
waveform, and <x> = 2 is the “to” waveform.
CH<x> is an input channel.
MATH or MATH1 is the math waveform.
REF<x> is a reference waveform.
MEASUREMENT:IMMED:SOURCE1 MATH1
specifies MATH1 as the immediate measurement source.
Arguments
Examples
Group
Syntax
Arguments
Examples

Table of Contents

Other manuals for Tektronix TDS3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS3000 Series and is the answer not in the manual?

Tektronix TDS3000 Series Specifications

General IconGeneral
BrandTektronix
ModelTDS3000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals