EasyManua.ls Logo

Tektronix TDS3000 Series - Page 295

Tektronix TDS3000 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 257
SAVe:SETUp (Set Only)
Saves the current front-panel setup into the specified internal setup location or
file. This is equivalent to selecting the Save Current Setup menu item in the
SAVE/RECALL menu.
Save and Recall
SAVe:SETUp { <NR1> | <file path> }
<NR1> is a value in the range from 1 to 10 and specifies a location. Any settings
that have been stored previously at this location will be overwritten.
<file path> is a quoted string that defines the file name and path. Input the file
path using the form <drive>/<dir>/<filename>. <drive> and one or more
<dir>s are optional. If you do not specify them, the oscilloscope will write the
file to the current directory. <filename> stands for a filename of up to 8
characters followed by a period (“.”) and a 3-char extension. We recommend you
use .SET for the extension to identify files that store setup data.
The current directory refers to the name of a directory as returned by the
FILESystem:CWD query.
SAVE:SETUP 5
saves the current front-panel setup in internal setup location 5.
SAVE:SETUP “TEK00000.SET“
saves the current front-panel setup to the file TEK00000.SET in the current
directory.
RECAll:SETUp, *RCL, *SAV
SAVe:WAVEform (Set Only)
Stores a waveform in one of four reference memory locations or a file. This
command is equivalent to selecting the Save Waveform menu item in the
SAVE/RECALL menu.
Save and Recall
SAVe:WAVEform <wfm>,{ REF<x> | <file path> }
Group
Syntax
Arguments
Examples
Related Commands
Group
Syntax

Table of Contents