R309 AT Commands
©2015 Telegesis (UK) Ltd - 107 - AT Command Manual (Rev 3.09)
S44 – Profile ID for xCASTs (volatile)
The profile ID for all messages.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Volatile
Parameters
XXXX
The profile ID of any xCAST message
Factory Default
Defined in S45
S45 – Initial Setting of S44
The initial setting of S44 stored in non volatile
memory
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
After Soft or Hard Reset
Storage
Non-Volatile
XXXX
The profile ID of any xCAST message
Factory Default
C091
S46 – Start-up Functionality 32-bit number
Volatile 32-bit register which can be used by
some of the build in functionality
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Volatile
XXXXXXXX
Factory Default
00000000
R303 – upgraded to 32-bit ●