EasyManua.ls Logo

Telegesis ETRX357-LR - Page 108

Telegesis ETRX357-LR
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R309 AT Commands
©2015 Telegesis (UK) Ltd - 108 - AT Command Manual (Rev 3.09)
Description
Register defining the Node’s power descriptor,
which can be read by remote nodes using
ZigBee compliant ZDO messaging.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The Power Descriptor as described in section
2.3.2.4 of the ZigBee specification.
Factory Default
C110
SW release
R302
Description
Register defining the Profile ID of the Node’s
endpoint 2.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The 16 bit Profile ID.
Factory Default
C091
SW release
R302
Description
Register defining the Device ID of the Node’s
endpoint 2
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The 16 bit device ID.
Factory Default
0000
SW release
R302