R309 AT Commands
©2015 Telegesis (UK) Ltd - 109 - AT Command Manual (Rev 3.09)
Description
Register defining the version of the device
attached to the Node’s endpoint 2
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
00XX
The 8 bit version preceded by two leading 0’s.
Factory Default
0000
SW release
R302
Description
Register defining the input cluster list of the
device attached to the Node’s endpoint 2
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
[XXXX,XXXX,XXXX,XXXX,XXXX,XXXX,
XXXX,XXXX,XXXX,XXXX,XXXX,XXXX]
A list of a maximum of 12 x 16 bit cluster IDs
separated by commas. The list may have any
length from 0 to 12 clusters
Example
ATS4B=1101,000D
Factory Default
0000
SW release
R302