R309 AT Commands
©2015 Telegesis (UK) Ltd - 110 - AT Command Manual (Rev 3.09)
Description
Register defining the output cluster list of the
device attached to the Node’s endpoint 2
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
[XXXX,XXXX,XXXX,XXXX,XXXX,XXXX,
XXXX,XXXX,XXXX,XXXX,XXXX,XXXX]
A list of a maximum of 12 x 16 bit cluster IDs
separated by commas. The list may have any
length from 0 to 12 clusters
Factory Default
0000
SW release
R302
Description
In an FFD, the register defining the amount of
time after which a mobile end device times out
of its parent’s child table if it has not polled.
In an MED, defines the delay between an MED
losing contact with its parent and reporting
“LostPAN”.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
After Soft or Hard Reset
Note
The timer tested according to S4D continues to
run in Power Mode 3
Storage
Non-Volatile
Parameters
00XX
8-bit number led by “00”, which represents the
timeout in quarter seconds. The default of
0x0014 results in a timeout of 5s.
Factory Default
0014
SW release
R302