R309 AT Commands
©2015 Telegesis (UK) Ltd - 113 - AT Command Manual (Rev 3.09)
Check for other devices on the network. If no other devices could be found for three
consecutive tries, set S11F to 1 to enable PWM, then attempt a rejoin using the current
network key each time this functionality is triggered. Note: No functionality on COOs
Check for other devices on the network. If no other devices could be found for three
consecutive tries, set S11F to 0 to disable PWM, then attempt a rejoin using the current
network key each time this functionality is triggered. Note: No functionality on COOs
Toggle PA0-7 (x=0-7) or PB0-7 (x=8-F)
Flash I/Ox (pull low) for 250ms. Note: can only be triggered by a timer, not an IRQ
Set PA0-7 (x=0-7) or PB0-7 (x=8-F) to 0
Set PA0-7 (x=0-7) or PB0-7 (x=8-F) to 1
The unit sends the contents of S3B to the networks sink.
The unit sends the contents of S3C to the networks sink.
Sends the reading of the lower 16 I/O pins, A/D1 & A/D2 or ADC0 & ADC1 and V
cc
as well
as an 8-bit transmission counter which increments with every transmission to the network’s
sink, and if no sink is known the unit will search for a sink immediately when bit 8 of S10 is
set.
Same as 0110, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
Send a Tracking Message to all nearby routers which will forward this message and the
RSSI reading to their nearest sink.
Same as 0112, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
Same as 0112, but tracking message doesn’t contain ADC readings to save power on
tracked device (TRACK2 Prompt)
Same as 0114, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
Send a Tracking Message to all nearby routers which will forward this message and the
RSSI reading to their nearest sink if the local RSSI reading is higher than the first three
digits of S3B (S3B is interpreted as snnsnn). S3B must be set in all routers
Same as 0116, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
Send a Tracking Message to all nearby routers which will forward this message and the
RSSI reading to their nearest sink if the local RSSI reading is higher than the second three
digits of S3B (S3B is interpreted as snnsnn). Tracking message does not contain ADC
readings to save power on tracked device (TRACK2 Prompt)
Same as 0118, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
Sends the contents of S3B as a RAW transmission.
Sends the contents of S3C as a RAW transmission.
Sends to the network’s sink the reading of the I/O, an 8-bit transmission counter which
increments with every transmission, the contents of S46 and the reading of any A/D [1..4]
enabled in S15. If no sink is known the unit will search for a sink immediately when bit 8 of
S10 is set
Same as 0130, but to charge an external RC timer PA3 is pulled high whilst sending the
data and left high impedance the rest of the time.
If I am a Sink advertise me for x hops (max. no. of hops: 30). If I am a COO create
aggregation routes needed for Trust Centre. NB message does not reach end devices
when parent already knows a sink address