R309 AT Commands
©2015 Telegesis (UK) Ltd - 25 - AT Command Manual (Rev 3.09)
+DASSR – Disassociate Remote Node from PAN (ZDO)
AT+DASSR:<address>
Where <address> can be a node’s EUI64,
Network address or address table index
Note
Use with care when targeting a Coordinator. It
will not be able to rejoin the PAN
Use on
All Devices
Remote Action
Node leaves PAN
Response
SEQ:XX
OK
or ERROR:<errorcode>
<errorcode> represents the error code explained
in section 3.
Instruct device to leave the PAN.
Prompt
LeftPAN
+N – Display Network Information
+N=<devicetype>,<channel>,<power>,
<PID>,<EPID>
or +N=NoPAN
followed by
OK
<devicetype> represents the node’s functionality
in the PAN (FFD,COO,ZED,SED,MED),
<power> the node’s output power in dBm,
<channel> the IEEE 802.15.4 radio channel (11-
26), <PID> the node’s PAN ID and <EPID> the
node’s extended PAN ID.