R309 AT Commands
©2015 Telegesis (UK) Ltd - 38 - AT Command Manual (Rev 3.09)
Execute Command
AT+SN[:nn]
All Telegesis devices which are up to nn hops
away are listed. If nn = 01 only direct
neighbours will reply and nn = 00 will search the
entire network.
Notes
- When no parameter is specified for nn,
30 is used by default.
- If used on nodes other than the COO
and a sink the command may be
unreliable
Use on
COO, Sink
Response
OK or ERROR<errorcode>
Prompts
FFD:<EUI64>,<Network address>[,syy,zz]
MED:<EUI64>,<Network address>[,syy,zz]
SED:<EUI64>,<Network address>[,syy,zz]
ZED:<EUI64>,<Network address>[,syy,zz]
Parameters
nn ranging from 00 to 30
<errorcode> represents the error code explained
in section 3. In case bit C of register S10 is set
the RSSI level (syy in dBm) and LQI (zz in
hexadecimal) of the last hop are displayed. For
a description of the LQI reading please see
section 7. Source route messages may also be
displayed.
SW release
R302
Execute Command
AT+KEYUPD
Updates the Network Key with a new key. If the
value in S08 is non-zero and is not the current
key, it will be used for the updated key. If S08 is
zero or the current key, a random value will be
generated.
Note
Can only be used on the Trust Centre
Use on
Trust Centre
Response
OK
or
ERROR<errorcode>
<errorcode> represents the error code explained
in section 3.
SW release
R302