User Manual CXE85X
59300464 Rev.005
9.12.2013 16(44)
Monitored parameters
The CXE85x monitored parameters are described in the table below. SNMP
traps, if enabled, are sent to user specified IP addresses.
The affected LED and factory default severity settings are presented next to
each parameter. All alarm severities (Major / Minor / Notification / Disabled) and
alarm limits can be fully configured by the user. See the "Monitoring" chapter for
more details.
Note that some alarm limits (e.g. RF output power) are factory configured so
that alarms will only appear when hardware specifications are exceeded. The
alarm limits should be reconfigured to match network parameters if more
precise monitoring is needed.
Alarm text Description LED
Default
severity
Optical input
power high
Optical input power level is above high limit. Optical Major & Minor
Optical input
power low
Optical input power level is below low limit. Optical Major & Minor
Temperature high
Internal temperature is above high limit.
Status
Major & Minor
Temperature low
Internal temperature is below low limit.
Status
Major & Minor
RF output power
high
RF output power is above high limit. Status -
RF output power
low
RF output power is below low limit. Status Minor
Power supply
failure
Internal +12 V voltage is out of range. If resetting
the unit doesn't help, it should be sent to service.
Status Major
Internal error
The unit has an internal error. If resetting the unit
doesn't help, it should be sent to service.
Status Major
Application
started
Unit was reset or rebooted during last minute. - Minor
Settings changed
Unit's settings have been modified by user during
last minute.
- Minor
Control port
activated
Control port has been activated by the software
based on user settings.
- Minor
Backup activated
(CXE852 only)
Optical input has been automatically switched to
input 2 due to missing signal in input 1.
- Minor
Table 5. CXE85x alarms