ADDRESS 4016 - PROGRAMMING OF ATTRIBUTES FOR PARTITION А
Attributes
Partition А
The attributes of Partition A are programmed at this address. Every attribute is activated with pressing
of a digit button with a respective number (from 1 to 4). The chosen attribute is indicated with activated
number of the pressed digit.
Next pressing of the same button number will deactivate the attribute. At end of the procedure at the
keyboard display have to active only the numbers of the assigned attributes.
More than one attribute can be assigned at this address.
1. Squeak
ARM
The siren will activate singly for 1 second when arming the Partition A in the system.
2. Squeak
DISARM
The siren will activate twice when disarming the Partition A in the system.
3. Auto-Arm
Enbl
Enabling the automatic arming of Partition A in the system for the
programmed ar ADDRESS 4014 Auto-ARM time.
Auto-Arm
Enbl
Indication
LED LCD
Disabled
3
Enabled
(3)
4. Auto Arm
Full/Stay
Automatic arming the Partition A with specifying the arming mode:
• Full
• Stay (the User can stay at some rooms).
Attribute
Indication
LED LCD
Full
4
Stay
(4)
ADDRESS 4017 - NUMBER FOR COMMUNICATION WITH PARTITION А
Number for
communica-
tion
A number for communication between Partition A and a central monitoring station is entered at this
address.
4 digits have to be entered. The valid digits are from 0 to 9 and symbols from A to F.
Default settings - FFFF
ADDRESSES 4020 ... 4024 - PROGRAMMING OF THE ATTRIBUTES FOR PARTITION B
The programming is the same as for ADDRESS 4010 - 4014.
Default settings - Same as PARTITION A
ADDRESS 4025 - FIRE SIGNAL DURATION FOR PARTITION B
FIRE Signal
Duration
Partition B
The duration of the alarm signal for a FIRE event at Partition A is assigned at this address.
Programming this address affects the performance of the programmable SIREN output.
Every click of a digital button alternatively changes the type of duration of the sound signal. The display
indication is shown in the tables.
Until a valid
user code is
entered
There is a FIRE alarm signal until a valid system
user or master user code is introduced.
Indication
LED
LCD
1 2 3 4 5 6
Until the Bell
Time at
Address
4012 ends.
The FIRE signal duration is set at address 4022
BELL TIME.
Indication
LED
LCD
(1) (2) (3) (4) (5) (6)
Default settings - Until a valid user code is entered
ADDRESSES 4026 and 4027 - PROGRAMMING OF THE ATTRIBUTES FOR PARTITION B
The programming is the same as for ADDRESS 4016 and 4017.
Default settings - Same as PARTITION A