SUPPLEMENTS - СА62 Alarm Control Panel 65
SUPPLEMENT С - Additional Information
Coding recordings in log events
The LOG Memory le can be viewed at ADDRESS 0024 in the Engineer menu (with entered valid engineer
code), at ADDRESS 300 in the Manager menu (with entered valid Manager code), and ADDRESS 1 in the
User menu (with entered valid user code with rights to view the log le).
In order to view a previous event press the ▼ button. In order to view a next event press the ▲ button. To
view additional information (xx is the user code or event zone number) press ENTER. Single click the ENTER
button to return to the list of events.
Recorded events can be viewed with the help of the table, which shows message coding within the system
and LED keypad indication. All possible combinations of keypad light-emitting diodes, the meaning of each
combination and the decoding of the specifying recording "xx" for the number of the user code or zone, are
shown for ease in reading log event recordings.
LED
Indication
Event
number
Description
1 Burglary alarm type activated / Activated zone with AUX attribute “24h Burglary”
2 Burglary alarm type deactivated / Restored zone with AUX attribute "24h Burglary"
3
Fire type alarm event in xx zone
4
Fire type restoring event in xx zone
5
Panic type alarm event in xx zone
6
Panic type restoring event in xx zone
7
Tamper type alarm event in xx zone
8
Tamper type restoring event in xx zone
9
Medical type alarm event in xx zone
10
Medical type restoring event in xx zone
11
Burglary Alarm type xx zone bypass
12
Burglary Alarm type xx zone bypass restoring
13
Fire type xx zone bypass
14
Fire type xx zone bypass restoring
15
Panic type xx zone bypass
16
Panic type xx zone bypass restoring
17
Tamper type xx zone bypass
18
Tamper type xx zone bypass restoring
19
Medical type xx zone bypass
20
Medical type xx zone bypass restoring
21
Disarm by xx user
22
Remote disarming by xx user
23
Disarming by key-switch in xx zone
24
Arming by xx user
25
Remote arming by xx user
26
Arming by key-switch in xx zone
27
Quick arm type arming