Installation and Programming Manual - СА62 Alarm Control Panel 47
7. PROGRAMMING OF PERIPHERAL DEVICES
7.1 Programming of Keyboards
At ADDRESSES 70хх are programmed the parameters and the attributes for the connected to the system keyboards.
Up to 4 keyboards can be connected in the system.
ATTENTION:
The keyboards models LED61, LCD62 and LCD62B DO NOT SUPPORT SIMULTANEOUSLY OPERATION WITH
THE BOTH PARTITIONS A and B.
Simultaneously operation with A and В partitions are supported from LED62, LED63VG SE, LCD63SE, LCD64
keyboards.
ADDRESS 7000 - CHECKING THE SET KEYBOARD ADDRESS
Keyboard
address
At this address the set with jumpers address of each keyboard can be checked.
The indication is hexadecimal.
ADDRESS 7010 - KEYBOARD 1 SETTINGS
Keyboard 1
Settings
At this address the Keyboard 1 parameters are assigned.
The digital buttons 1 to 6 are used for programming. Pressing them each time will alternatively change
the status of the parameter - active / inactive. At the end of the procedure only those parameters, which
correspond to the desired settings, should remain activated on the display.
Note: If a keyboard is attached to neither of the partitions, it can not control the system - arming,
disarming, bypass and etc. The user can only enter the engineer menu and do some settings in the
system.
At the default settings the display will show:
LED
LCD
(1) 2 3 4 5 (6)
1. PART A The keyboard is attached to Partition А. The User can perform actions in Partition A*.
2. PART B The keyboard is attached to Partition В. The User can perform actions in Partition B**.
3. Chime
disable
This is local setting for the keyboard. When the attribute is assigned
the keyboard will not produce the "Chime" sound signal.
Attribute
Indication
LED LCD
OFF
3
ON
(3)
4. Keypad
zone
With this attribute is assigning the number of the keyboard zone - 1 or
7. With set parameter the keyboard will be zone 7. See also the table
on the right.
Keypad
zone
Indication
LED LCD
ZONE 1
4
ZONE 7
(4)
5. Silent
Panic
With this attribute is assigned, in case of sent PANIC alarm signal from
the keyboard, the siren will not sound.
Attribute
Indication
LED LCD
Disabled
5
Enabled
(5)
6. Zone
Enable
With this attribute the engineer can disable or enable the keyboard
zone.
Attribute
Indication
LED LCD
Disabled
6
Enabled
(6)
Default settings - PART A, Zone Enable
* User with a personal code with rights to operate in Partition A. User code with rights to operate only with Partition B will
be rejected.
** User with a personal code with rights to operate in Partition B. User code with rights to operate only with Partition A will
be rejected.