48 Installation and Programming Manual - СА62 Alarm Control Panel
ADDRESS 7011 - LEFT ARROW BUTTON OF KEYBOARD 1
"Left arrow"
button of
Keyboard1
At this address the arming mode of the system with the "left arrow" button of the keyboard 1 is as-
signed.
The digital buttons 1 to 6 are used for programming. Pressing them each time will alternatively change
the status of the parameter - active / inactive.
Only one attribute can be assigned.
1. Full Arm
PART A
Full arming mode for PARTITION А.
2. Stay Arm
PART A
Stay arming mode for PARTITION А - the user is allowed to stay in certain zones in PARTITION A.
3. Stay Arm
Part В
Stay arming mode for PARTITION B - the user is allowed to stay in certain zones in PARTITION B.
4. Inst Arm
Part А
Instant arming mode of PARTITION А.
5. Inst Arm
Part B
Instant arming mode of PARTITION B.
6. Arm
Following
The arming of the partition(s) is with specifying the arming mode type: Full, Stay or Instant.
Example:
With assigning this parameter, the system arming will be as follows:
◄ (left arrow) + 0 - Full Arming Mode
◄ (left arrow) + 1 - Stay Arming Mode
◄ (left arrow) + 2 - Instant Arming Mode
Default settings - Arm Following
ADDRESS 7012 - RIGHT ARROW BUTTON OF KEYBOARD 1
"Right arrow"
button of
Keyboard1
At this address the arming mode of the system with the "right arrow" button of the keyboard 1 is as-
signed.
The digital buttons 1 to 6 are used for programming. Pressing them each time will alternatively change
the status of the parameter - active / inactive.
Only one attribute can be assigned.
1. Full Arm
PART В
Full arming mode for PARTITION В.
2. Stay Arm
PART A
Stay arming mode for PARTITION А - the user is allowed to stay in certain zones in PARTITION A.
3. Stay Arm
Part В
Stay arming mode for PARTITION B - the user is allowed to stay in certain zones in PARTITION B.
4. Inst Arm
Part А
Instant arming mode of PARTITION А.
5. Inst Arm
Part B
Instant arming mode of PARTITION B.
6. Arm
Following
The arming of the partition(s) is with specifying the arming mode type: Full, Stay or Instant.
Example:
With assigning this parameter, the system arming will be as follows:
► (right arrow) + 0 - Full Arming Mode
► (right arrow) + 1 - Stay Arming Mode
► (right arrow) + 2 - Instant Arming Mode
Default settings - Arm Following
ADDRESS 7013 - ARM BUTTON FOR KEYBOARD 1
ARM Button
Keyboard 1
At this address the function of "ARM" button of the keyboard 1 is assigned.
Note: In the LED62 the button
corresponds to ARM button.
The digital buttons 1, 2 and 6 are used for programming. Pressing them each time will alternatively
change the status of the parameter - active / inactive.
Only one attribute can be assigned.
1. No ARM The ARM button is disabled for arming the system.
2. Full
ARM All
The ARM button is enabled for Full arming of the partition(s) to which the keyboard is attached. DIS-
ARMING the both Partitions with one button (ARM) will function only, when at ADDRESS 7010 both
attributes 1. PART A and 2. PART B are assigned.