SUPPLEMENTS - СА62 Alarm Control Panel 67
Table of protocol Contact ID transmitted codes from CA62
Code Description
100 - Medical alarm Medical alarm
110 - Fire alarm Fire alarm
120 - Panic alarm Panic alarm
121 - Ambush code Code entered under ambush
130 - Burglary alarm Alarm
133 - 24 h Burglary 24-hour Burglary type zone
137 - Tamper alarm Tamper alarm
138 - Оpening of zone with attr. Write to log Activated zone with attribute "Write to log"
151 - Gas detector Activated gas detector
152 - Refrigeration Activated refrigeration sensor
153 - Loss of heat Loss of heat (activated heat sensor)
154 - Water leakage Activated water leakage detector
155 - Foil Break Foil break
157 - Low bottled gas level Low bottled gas level
158 - High temperature High temperature in the premises
159 - Low temperature Low temperature in the premises
300 - System trouble Trouble in the system
301 - AC Loss No 220 V power supply
302 - Battery low Low battery charging level
305 - System RESET System parameters default reset
311 - Battery missing The battery is lost
330 - GSM link trouble GSM Communication failure
338 - Closing of zone with attr. Write to log Restored zone with attribute "Write to log"
351 - Teleco Fail Telephone line failure
354 - Failure to communicate Communication error
401 - Open/Close by user Arming/ Disarming by user
407 - Remote Arm/ Disarm Remote Arming/Disarming
408 - Quick arm Quick arming (no code)
409 - Keyswitch Open/Close Arming/Disarming from key-switch
571 - Fire bypass Bypassing a FIRE type zone
572 - 24 h zone bypass Bypassing a 24 h Burglary type zone
573 - Burglary bypass Bypassing an Entry/Exit, Follow or Instant type zone
601 - Manual TEST report Manual TEST signal
602 - Periodic TEST report Periodic TEST signal
627 - Program mode entry Engineer programming mode entry
628 - Program mode exit Engineer programming mode exit