Installation and Programming Manual - СА62 Alarm Control Panel 49
6. Arm *
Following
The arming of the partition(s) is with specifying the arming mode type: Full, Stay or Instant.
Example:
With assigning this parameter, the system arming will be as follows:
ARM or + 0 - Full Arming Mode
ARM or + 1 - Stay Arming Mode
ARM or + 2 - Instant Arming Mode
* NOTE: The Arm Following procedure is applied to user codes attached only to one of the Partitions.
Default settings - Arm Following
ADDRESSES 7020 ... 7023 – KEYBOARD 2 PROGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 2.
Default settings: Conguration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following
ADDRESSES 7030 ... 7033 – KEYBOARD 3 PROGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 3.
Default settings: Conguration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following
ADDRESSES 7040 ... 7043 – KEYBOARD 4 PROGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 4.
Default settings: Conguration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following
7.2 Programming of Proxi Readers
At ADDRESSES 71хх are programmed the parameters and the attributes for the connected to the system proximity
card readers. Up to 2 readers can be connected in the system.
ADDRESS 7100 - PROXI READER 1 SETTINGS
Proxi 1
Settings
At this address the parameters of Proxi Reader 1 are assigned.
Pressing them each time will alternatively change the status of the parameter - active / inactive.
Note: Every Proxi Reader can be attached to the both partitions in the system. In this case, if a proxi
card with user rights for the both partitions in the system is approached to the reader - the both parti-
tions will be armed or disarmed according their current status. If the one partition is armed and the
other is disarmed, then approaching the same user card will disarm the armed partition. The next ap-
proaching of the user card will arm the both partitions again.
At the default settings the display will show:
LED
LCD
(1) 2 3 4 5 6
1. PART A
The Proxi Reader is attached to Partition А.
Note: When the Proxi Reader is attached to Partition A only, then with approaching a user card with the
respective rights, if the Partition A is disarmed - it arms, if the Partition A is armed - it disarms.
2. PART B
The Proxi Reader is attached to Partition В.
Note: When the Proxi Reader is attached to Partition B only, then with approaching a user card with
the respective rights, if the Partition A is disarmed - it arms, if the Partition B is armed - it disarms.
Default settings - PART A
ADDRESS 7110 - PROXI READER 2 SETTINGS
The programming is the same as ADDRESS 7100, as the programming is for Proxi Reader 2.
Default settings: PART А