20 Installation and Programming Manual - СА62 Alarm Control Panel
0. ENGINEER PARAMETERS AND COMMON SETTINGS
ADDRESS 0000 - CHANGING THE ENGINEER CODE
Engineer
code
A new access code to the alarm station engineer parameters can be assigned at this address.
Note: If the 6-digit long access code is set, the combination "00" automatically will be added at the end
of all valid codes in the system (see also the description of ADDRESS 1001).
Indication
LED
LCD
1 2 (3) (4) (5) (6)
The light-emitting diodes 3, 4, 5 and 6 on the keypad display light up. These go out one by one as the
new code is entered. The new code has to be entered a second time.
Default settings
- 7777
ADDRESS 0001 - HARDWARE RESET ENABLE
Reset
Enable
Disables or enables the hardware RESET of the alarm station. Specialized service is required where
the hardware RESET is disabled and the engineer code is obscure.
The parameter status can be changed with pressing of random button of the keyboard.
NO The hardware RESET is disabled.
Indication
LED
LCD
1 2 3 4 5 6
YES The hardware RESET is enabled.
Indication
LED
LCD
(1) (2) (3) (4) (5) (6)
Default conguration
- YES
ADDRESS 0002 - RESTORING DEFAULT PARAMETERS (SOFTWARE RESET)
Default
settings
Restoration of default settings of the station. The buttons 1, 2, 3, 4, 5, 6 are pressed in succession and
conrmed with the ENTER button.
ADDRESS 0003 - RESTORING DEFAULT MANAGER CODE (PARTIAL SOFTWARE RESET)
Partial reset
Restoration of the default manager code. Buttons 1, 2, 3, 4, 5, 6 are pressed in succession and con-
rmed with the ENTER button.
The station restores the default 0000 manager user code.
ADDRESS 0010 - AUTHORITY TO ARM USING A ONE PUSH-BUTTON (QUICK ARM)
Quick ARM
Enable
A quick Arming mode using one button, without need to enter a valid user code is assigned at this ad-
dress. The assigning can be done for PARTITION A, PARTITION B or for both partitions.
The parameter is activated with pressing a digit number corresponding to the partition number - 1 for
PARTITION A and 2 for PARTITION B. Next pressing of the button will deactivate the parameter.
PARTITION
A
Quick Arming of PARTITION A without legal user
code.
Indication
LED
LCD
(1) 2 3 4 5 6
PARTITION
B
Quick Arming of PARTITION B without legal user
code.
Indication
LED
LCD
1 (2) 3 4 5 6
Default conguration
- PARTITION A, PARTITION B