Fallback firmware (socalled "Golden" version, version programmed during production process)
will not be impacted by a CRP update. This firmware is used as a bootloader and used as fallback
in case a failure occurs and unit doesn’t boot to application software.
Different fallback firmware versions have no influence on the functional performance of the
system.
To be able to update the Confidea G3 WCAP and units, you need to uncouple these from the
Plixus system and perform the update using the Confidea G3 web server. See the Confidea G3
user guide for more information.
Update Versions
Under Version you can find a list with all devices in the network (also units that are not yet initialized).
Click Download overview to get a .txt file that contains all devices together with their serial numbers and
firmware versions. You can use this as reference before the update.
If the system discovers a version mismatch, you will get an error message showing which devices are
affected.