Indicators and Diagnostics
Page 4-12
Troubleshooting Outgoing Calls
NET-PATH does not go off-hook.
Possible Cause:
Incorrect database. Event is not programmed, is not programmed correctly, cur-
rent time is not in the Action window, or event duration is too long.
No App loaded.
Incoming calls are not received at the Polling and Analysis Center.
Possible Cause:
Bad database. Incorrect telephone number.
Modem at the receiving end is not set for auto-answer.
Restricted telephone line. Contact your local telephone representative.
Call was received at the Polling and Analysis Center, but did not have a carrier.
Possible Cause:
Non-compatible or defective modem at the Polling and Analysis Center.
The modem at Polling and Analysis Center is not in data mode.
You selected an incorrect database option.
Call received at Polling and Analysis Center, modem connected, but message not
received.
Possible Cause:
Bad database. Incorrect protocol flag.
Bad telephone line. Contact your local telephone representative.
Incorrect receiving option (parity, speed, stop bits, data bits)