EasyManua.ls Logo

Tennant 5280 - While Operating Machine; Circuit Breakers; Operating Off-Aisle Wand (Option)

Tennant 5280
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
Tennant 5280 (10–00)
15
WHILE OPERATING MACHINE
WARNING: Flammable materials or
reactive metals can cause explosion or fire.
Do not pick up.
1. Overlap each path by 50 mm (2 in).
2. Keep machine moving to prevent damage to finish
or floor.
3. Avoid floor obstructions, such as grates, to
prevent pad damage.
4. Periodically observe recovery tank for excessive
foam. Pour a recommended foam control solution
into recovery tank if excessive foam appears.
ATTENTION: Do not allow foam or water to enter
float shut-off screen, vacuum motor damage will
result; not covered by warranty. Foam will not
activate float shut-off screen.
5. For heavily soiled areas, double scrubbing is
recommended. First scrub area with squeegee up,
let solution set for 15–20 minutes, then scrub area
a second time with squeegee down.
ATTENTION: Do not operate machine with pad
pressure meter in red zone, circuit breakers will
trip and floor damage may occur.
6. Change or turn pads over when worn.
7. If squeegee leaves streaks, raise and wipe blades
with a cloth. Pre-sweep area to prevent streaking.
8. Observe battery discharge indicator. When needle
drops to the red zone, stop scrubbing and
recharge batteries (Figure 32).
ATTENTION: Do not operate machine with battery
discharge indicator in this red zone, battery
damage will result.
FIG. 32
CIRCUIT BREAKERS
The machine is equipped with three resettable circuit
breakers. They are designed to stop current flow in the
event of a circuit overload. If a circuit breaker should
trip during operation, determine cause, allow breaker
to cool and then manually reset breaker. Circuit
breaker panel is located at rear of machine
(Figure 33).
– 7 A Main Circuit Breaker
– 17 A Vacuum Motor Circuit Breaker
– 35 A Brush Motor Circuit Breaker
FIG. 33
OPERATING OFF-AISLE WAND (OPTION)
The off–aisle wand allows you to scrub/vacuum areas
that the machine is unable to reach.
1. Turn machine power off.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, and turn off
machine.
2. Disconnect squeegee vacuum hose from
squeegee assembly (Figure 34).
FIG. 34