BHT-212-MM-1
5-00-00
Page 46 Rev. 14 26 JUN 2013
Export Classification C, ECCN EAR99
RIGHT POWER SECTION
Refer to Pratt & Whitney Canada PT6T-3/-3B
Maintenance Manual for engine inspection
requirements.
Every third 100 hour inspection (300 hours) or 12 months:
— Detailed Visual Inspection
1. Ignition leads for corrosion, chafing and security.
2. Chip detectors for debris.
— Restoration
1. Clean chip detectors.
— Functional Check
1. Test chip detectors electrical circuits.
Chapter 76 ENGINE FUEL AND POWER CONTROLS
Every third 100 hour inspection (300 hours) or 12 months:
— Operational Check
1. Check controls for smooth movement through full travel
ranges.
Chapter 71 STARTER GENERATOR
Every third 100 hour inspection (300 hours) or 12 months.
— Detailed Visual Inspection
1. Left power section starter generator cooling ducts for
obstruction, kinking, and security.
5-9. 100 HOURS/12 CALENDAR MONTHS — PART A (CONT)
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER