AS 680/682
Description, Operation and Maintenance Supervisor Operation
ADS−B
5−17Ed. 10.07
5.4.5 Page ’Groundstation’
This page, see Fig. 5−9, presents basic information about the Ground Station’s operational mode.
Fig. 5−9 Page ’Groundstation’ (example)
5.4.5.1 Ground Station Identification
The name of the Ground Station or the System Area Code (SAC) and System Identification Code (SIC)
identify a Ground Station. SIC and SAC identify a system, uniquely worldwide. They are defined by
Eurocontrol in the Asterix standard documents.
5.4.5.2 Time Synchronization
It is possible to enable the ’GPS ’ module to be able to synchronise the Ground Station’s internal clock
based on GPS. It is possible to synchronise the Ground Station’s system time based on NTP or based
on the GPS. The Ground Station’s clock is not synchronised, if the option ’none’ is selected. Chang-
ing the base of the time synchronisation, a confirmation panel pops up telling that the application must
manually be restarted.