AS 680/682
Installation and Setup Description, Operation and Maintenance
ADS−B
3−20 Ed. 10.07
e) Open a terminal, set the mouse pointer in it and press the left mouse button.
f) After entering the command minicom <enter> you are connected to the Site Monitor.
g) Switch on the Site Monitor.
h) On the LCMS terminal window, the Site Monitor prompt
FM−VERSION: [1.1]
BITE STATUS: [OK]
is displayed.
i) Set or check the Site Monitor parameters:
Entering the command getall <enter> will show the values of all parameters. A single parame-
ter can be accessed by getparparameter name<enter>. The value of a parameter can be
changed by setparparameter name’ ‘value’ <enter>. Entering help <enter> will show all pa-
rameters and their valid values. Verify the parameters (and change them if needed) according to
the following table:
Parameter Name Value Remark
DF
ADDRESS
PERIOD
JITTER
18
<3C3D0C>
0.5
1
Downlink format of Site Monitor messages
Use Mode−S address in SM messages (customer defined).
Repetition rate of Site Monitor messages
Transmission period will be jittered.
j) Check the parameter setting by entering getall <enter> again.
k) Enter the command setall <enter> to store changes permanently in the flash EPROM.
3.2.9 Initial Ground Station Settings AS682
It is supposed that the initial GS settings (network parameters) have already be done by the Thales
ATM service personnel. The GS is ready for operation.
3.2.10 Site Monitor Settings AS682
It is supposed that the initial Site Monitor settings (operational parameters) have already be done by
the Thales ATM service personnel. The SM is ready for operation.