cutmaster a60
INSTALLATION 3-2 Manual 0-4981
A. Cover Removal
1. Remove the upper and lower screws
which secure the cover to the main assem-
bly. Do not loosen the lower screws inside
the cut out slots in the bottom of the cover.
Note
The upper screws and lower screws are not the
same. Do not mix them. The upper screws are
for threading into the plastic of the front and rear
panels. DO NOT use the finer threaded lower
screws for this.
Upper
Screws
Lower
Screws
Lower
Screws
Art # A-08317
Slots
2. Carefully pull the Cover up and away from
the unit.
B. Cover Installation
1. Reverse previous procedures for cover
installation.
NOTE
When installing the upper screws, attempt to
reuse the original threads. The easaiest way to
do this is by turning the screw counter-clockwise
until you feel the threads lign up, then begin to
turn the screw clockwise to tighten. Do not over
tighten.
C. Input Power Selection
Set the Input Voltage Selection Switch at the rear
of the unit based on the primary input voltage it
is connected to. Low is 208/230 VAC and high is
460 VAC.
D. Quick Guide to Phase Wiring
Art # A-07984_AB
Single-Phase (1ø) and Jumper Settings
L1
L2
L3
L4
Jumper L1 -L4
Jumper
L2-L3
L1
L2
L3
GND
L4
Single Phase Input Power Wiring
Art # A-07983_AB
Three-Phase (3ø) and Jumper Settings
L1
L2
L3
L4
Jumper L1 -L4
L1
L2
L3
GND
L4
Store copper jumper in spare parts box
Three Phase Input Power Wiring
NOTE
There is only one jumper setting that changes
between the single and three phase settings. To
change from single phase to three phase, the copper
bus bar jumper connected to L2 and L3 needs to be
removed and placed in a safe place for re-use. We
suggest the spare parts box in the power supply.
See previous illustrations.