cutmaster a120
SERVICE 5-8 Manual 0-4989
Optional Two-Stage Filter Element
Replacement
The Two-Stage Air Filter has two Filter Elements. When
the Filter Elements become dirty the Power Supply will
continue to operate but cut quality may become unac-
ceptable. Refer to Section 6, Parts List, for replacement
filter element catalog number.
1. Shut off primary input power.
2. Shut off air supply and bleed down system.
WARNING
Always turn off the air supply and bleed the sys-
tem before disassembling the Filter Assembly as
injury could result.
3. Loosen the two bolts on the top of the Filter As-
sembly enough to allow the Filter Elements to
move freely.
4. Note the location and orientation of the old Filter
Elements.
5. Slide out the old Filter Elements.
First & Second
Stage
Cartridges
(as marked)
Art # A-02942
Optional Two-Stage Filter Replacement
6. Slide the replacement Filter Elements into the
Filter Assembly, with the same orientation as
noted in Step 4 above.
7. Hand tighten the two bolts evenly, then torque
each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper
torque may damage the gasket.
8. Slowly apply air pressure to the assembly, check-
ing for leaks.
NOTE
A small amount of air leakage from the bottom
fitting is normal.
This completes the parts replacement procedures.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermal Dynamics CUTMASTER A80 and is the answer not in the manual?

Thermal Dynamics CUTMASTER A80 Specifications

General IconGeneral
BrandThermal Dynamics
ModelCUTMASTER A80
CategoryCutter
LanguageEnglish

Related product manuals