Manual 0-4989 2-3 INTRODUCTION
2.05 Input Wiring Specifications
CutMaster A120 Power Supply Input Cable Wiring Requirements
Input voltage Freq Power Input Suggested Sizes
Volts Hz kVA I max I eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
1 Phase
208 60 26.2 126 115 150 4 Type W
230 60 27.6 120 106 125 4 Type W
460 60 35 76 38 100 8
3 Phase
208 60 21.6 60 55 60 4
230 60 22.3 56 50 60 4
380 50 23 35 32 40 8
400 50 23.6 34 31 40 8
460 60 29.5 37 33 40 8
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code